2017-12-16 12:53:48 +00:00
|
|
|
<!-- file * -->
|
|
|
|
<!-- struct NetClientClock -->
|
|
|
|
`NetClientClock` implements a custom `gst::Clock` that synchronizes its time
|
|
|
|
to a remote time provider such as `NetTimeProvider`. `NtpClock`
|
|
|
|
implements a `gst::Clock` that synchronizes its time to a remote NTPv4 server.
|
|
|
|
|
|
|
|
A new clock is created with `NetClientClock::new` or
|
|
|
|
`NtpClock::new`, which takes the address and port of the remote time
|
|
|
|
provider along with a name and an initial time.
|
|
|
|
|
|
|
|
This clock will poll the time provider and will update its calibration
|
|
|
|
parameters based on the local and remote observations.
|
|
|
|
|
|
|
|
The "round-trip" property limits the maximum round trip packets can take.
|
|
|
|
|
|
|
|
Various parameters of the clock can be configured with the parent `gst::Clock`
|
|
|
|
"timeout", "window-size" and "window-threshold" object properties.
|
|
|
|
|
|
|
|
A `NetClientClock` and `NtpClock` is typically set on a `gst::Pipeline` with
|
|
|
|
`gst::Pipeline::use_clock`.
|
|
|
|
|
|
|
|
If you set a `gst::Bus` on the clock via the "bus" object property, it will
|
|
|
|
send `gst::MessageType::Element` messages with an attached `gst::Structure` containing
|
|
|
|
statistics about clock accuracy and network traffic.
|
|
|
|
|
|
|
|
# Implements
|
|
|
|
|
2017-12-22 11:37:28 +00:00
|
|
|
[`gst::ClockExt`](../gst/trait.ClockExt.html), [`gst::ObjectExt`](../gst/trait.ObjectExt.html), [`glib::object::ObjectExt`](../glib/object/trait.ObjectExt.html)
|
2017-12-16 12:53:48 +00:00
|
|
|
<!-- impl NetClientClock::fn new -->
|
|
|
|
Create a new `GstNetClientInternalClock` that will report the time
|
|
|
|
provided by the `NetTimeProvider` on `remote_address` and
|
|
|
|
`remote_port`.
|
|
|
|
## `name`
|
|
|
|
a name for the clock
|
|
|
|
## `remote_address`
|
|
|
|
the address or hostname of the remote clock provider
|
|
|
|
## `remote_port`
|
|
|
|
the port of the remote clock provider
|
|
|
|
## `base_time`
|
|
|
|
initial time of the clock
|
|
|
|
|
|
|
|
# Returns
|
|
|
|
|
|
|
|
a new `gst::Clock` that receives a time from the remote
|
|
|
|
clock.
|
|
|
|
<!-- struct NetTimeProvider -->
|
|
|
|
This object exposes the time of a `gst::Clock` on the network.
|
|
|
|
|
|
|
|
A `NetTimeProvider` is created with `NetTimeProvider::new` which
|
|
|
|
takes a `gst::Clock`, an address and a port number as arguments.
|
|
|
|
|
|
|
|
After creating the object, a client clock such as `NetClientClock` can
|
|
|
|
query the exposed clock over the network for its values.
|
|
|
|
|
|
|
|
The `NetTimeProvider` typically wraps the clock used by a `gst::Pipeline`.
|
|
|
|
|
|
|
|
# Implements
|
|
|
|
|
2017-12-22 11:37:28 +00:00
|
|
|
[`gst::ObjectExt`](../gst/trait.ObjectExt.html), [`glib::object::ObjectExt`](../glib/object/trait.ObjectExt.html)
|
2017-12-16 12:53:48 +00:00
|
|
|
<!-- impl NetTimeProvider::fn new -->
|
|
|
|
Allows network clients to get the current time of `clock`.
|
|
|
|
## `clock`
|
|
|
|
a `gst::Clock` to export over the network
|
|
|
|
## `address`
|
|
|
|
an address to bind on as a dotted quad
|
|
|
|
(xxx.xxx.xxx.xxx), IPv6 address, or NULL to bind to all addresses
|
|
|
|
## `port`
|
|
|
|
a port to bind on, or 0 to let the kernel choose
|
|
|
|
|
|
|
|
# Returns
|
|
|
|
|
|
|
|
the new `NetTimeProvider`, or NULL on error
|
|
|
|
<!-- struct NtpClock -->
|
|
|
|
|
|
|
|
|
|
|
|
# Implements
|
|
|
|
|
2017-12-22 11:37:28 +00:00
|
|
|
[`NetClientClockExt`](trait.NetClientClockExt.html), [`gst::ClockExt`](../gst/trait.ClockExt.html), [`gst::ObjectExt`](../gst/trait.ObjectExt.html), [`glib::object::ObjectExt`](../glib/object/trait.ObjectExt.html)
|
2017-12-16 12:53:48 +00:00
|
|
|
<!-- impl NtpClock::fn new -->
|
|
|
|
Create a new `NtpClock` that will report the time provided by
|
|
|
|
the NTPv4 server on `remote_address` and `remote_port`.
|
|
|
|
## `name`
|
|
|
|
a name for the clock
|
|
|
|
## `remote_address`
|
|
|
|
the address or hostname of the remote clock provider
|
|
|
|
## `remote_port`
|
|
|
|
the port of the remote clock provider
|
|
|
|
## `base_time`
|
|
|
|
initial time of the clock
|
|
|
|
|
|
|
|
# Returns
|
|
|
|
|
|
|
|
a new `gst::Clock` that receives a time from the remote
|
|
|
|
clock.
|
|
|
|
<!-- struct PtpClock -->
|
|
|
|
GstPtpClock implements a PTP (IEEE1588:2008) ordinary clock in slave-only
|
|
|
|
mode, that allows a GStreamer pipeline to synchronize to a PTP network
|
|
|
|
clock in some specific domain.
|
|
|
|
|
|
|
|
The PTP subsystem can be initialized with `gst_ptp_init`, which then starts
|
|
|
|
a helper process to do the actual communication via the PTP ports. This is
|
|
|
|
required as PTP listens on ports < 1024 and thus requires special
|
|
|
|
privileges. Once this helper process is started, the main process will
|
|
|
|
synchronize to all PTP domains that are detected on the selected
|
|
|
|
interfaces.
|
|
|
|
|
|
|
|
`PtpClock::new` then allows to create a GstClock that provides the PTP
|
|
|
|
time from a master clock inside a specific PTP domain. This clock will only
|
|
|
|
return valid timestamps once the timestamps in the PTP domain are known. To
|
|
|
|
check this, you can use `gst::ClockExt::wait_for_sync`, the GstClock::synced
|
|
|
|
signal and `gst::ClockExt::is_synced`.
|
|
|
|
|
|
|
|
To gather statistics about the PTP clock synchronization,
|
|
|
|
`gst_ptp_statistics_callback_add` can be used. This gives the application
|
|
|
|
the possibility to collect all kinds of statistics from the clock
|
|
|
|
synchronization.
|
|
|
|
|
|
|
|
# Implements
|
|
|
|
|
2017-12-22 11:37:28 +00:00
|
|
|
[`gst::ClockExt`](../gst/trait.ClockExt.html), [`gst::ObjectExt`](../gst/trait.ObjectExt.html), [`glib::object::ObjectExt`](../glib/object/trait.ObjectExt.html)
|
2017-12-16 12:53:48 +00:00
|
|
|
<!-- impl PtpClock::fn new -->
|
|
|
|
Creates a new PTP clock instance that exports the PTP time of the master
|
|
|
|
clock in `domain`. This clock can be slaved to other clocks as needed.
|
|
|
|
|
|
|
|
If `gst_ptp_init` was not called before, this will call `gst_ptp_init` with
|
|
|
|
default parameters.
|
|
|
|
|
|
|
|
This clock only returns valid timestamps after it received the first
|
|
|
|
times from the PTP master clock on the network. Once this happens the
|
|
|
|
GstPtpClock::internal-clock property will become non-NULL. You can
|
|
|
|
check this with `gst::ClockExt::wait_for_sync`, the GstClock::synced signal and
|
|
|
|
`gst::ClockExt::is_synced`.
|
|
|
|
## `name`
|
|
|
|
Name of the clock
|
|
|
|
## `domain`
|
|
|
|
PTP domain
|