This then just counts samples and calculates the output timestamps based
on that and the very first observed timestamp. The timestamps on the
buffers are continued to be used to detect discontinuities that are too
big and reset the counter at that point.
When receiving data via Bluetooth, many devices put completely wrong
values into the RTP timestamp field. For example iOS seems to put a
timestamp in milliseconds in there, instead of something based on the
current sample offset (RTP clock-rate == sample rate).
https://bugzilla.gnome.org/show_bug.cgi?id=787297