Clocks and synchronization in &GStreamer;
When playing complex media, each sound and video sample must be played in a
specific order at a specific time. For this purpose, GStreamer provides a
synchronization mechanism.
&GStreamer; provides support for the following use cases:
Non-live sources with access faster than playback rate. This is
the case where one is reading media from a file and playing it
back in a synchronized fashion. In this case, multiple streams need
to be synchronized, like audio, video and subtitles.
Capture and synchronized muxing/mixing of media from multiple live
sources. This is a typical use case where you record audio and
video from a microphone/camera and mux it into a file for
storage.
Streaming from (slow) network streams with buffering. This is the
typical web streaming case where you access content from a streaming
server with http.
Capture from live source and and playback to live source with
configurable latency. This is used when, for example, capture from
a camera, apply an effect and display the result. It is also used
when streaming low latency content over a network with UDP.
Simultaneous live capture and playback from prerecorded content.
This is used in audio recording cases where you play a previously
recorded audio and record new samples, the purpose is to have the
new audio perfectly in sync with the previously recorded data.
&GStreamer; uses a GstClock object, buffer
timestamps and a SEGMENT event to synchronize streams in a pipeline
as we will see in the next sections.
Clock running-time
In a typical computer, there are many sources that can be used as a
time source, e.g., the system time, soundcards, CPU performance
counters, ... For this reason, there are many
GstClock implementations available in &GStreamer;.
The clock time doesn't always start from 0 or from some known value.
Some clocks start counting from some known start date, other clocks start
counting since last reboot, etc...
A GstClock returns the
absolute-time
according to that clock with gst_clock_get_time ().
The absolute-time (or clock time) of a clock is monotonically increasing.
From the absolute-time is a running-time
calculated, which is simply the difference between a previous snapshot
of the absolute-time called the base-time.
So:
running-time = absolute-time - base-time
A &GStreamer; GstPipeline object maintains a
GstClock object and a base-time when it goes
to the PLAYING state. The pipeline gives a handle to the selected
GstClock to each element in the pipeline along
with selected base-time. The pipeline will select a base-time in such
a way that the running-time reflects the total time spent in the
PLAYING state. As a result, when the pipeline is PAUSED, the
running-time stands still.
Because all objects in the pipeline have the same clock and base-time,
they can thus all calculate the running-time according to the pipeline
clock.
Buffer running-time
To calculate a buffer running-time, we need a buffer timestamp and
the SEGMENT event that preceeded the buffer. First we can convert
the SEGMENT event into a GstSegment object
and then we can use the
gst_segment_to_running_time () function to
perform the calculation of the buffer running-time.
Synchronization is now a matter of making sure that a buffer with a
certain running-time is played when the clock reaches the same
running-time. Usually this task is done by sink elements. Sink also
have to take into account the latency configured in the pipeline and
add this to the buffer running-time before synchronizing to the
pipeline clock.
Non-live sources timestamp buffers with a running-time starting
from 0. After a flushing seek, they will produce buffers again
from a running-time of 0.
Live sources need to timestamp buffers with a running-time matching
the pipeline running-time when the first byte of the buffer was
captured.
Buffer stream-time
The buffer stream-time, also known as the position in the stream,
is calculated from the buffer timestamps and the preceding SEGMENT
event. It represents the time inside the media as a value between
0 and the total duration of the media.
The stream-time is used in:
Report the current position in the stream with the POSITION
query.
The position used in the seek events and queries.
The position used to synchronize controlled values.
The stream-time is never used to synchronize streams, this is only
done with the running-time.
Time overview
Here is an overview of the various timelines used in &GStreamer;.
The image below represents the different times in the pipeline when
playing a 100ms sample and repeating the part between 50ms and
100ms.
You can see how the running-time of a buffer always increments
monotonically along with the clock-time. Buffers are played when their
running-time is equal to the clock-time - base-time. The stream-time
represents the position in the stream and jumps backwards when
repeating.
Clock providers
A clock provider is an element in the pipeline that can provide
a GstClock object. The clock object needs to
report an absoulute-time that is monotonocally increasing when the
element is in the PLAYING state. It is allowed to pause the clock
while the element is PAUSED.
Clock providers exist because they play back media at some rate, and
this rate is not necessarily the same as the system clock rate. For
example, a soundcard may playback at 44,1 kHz, but that doesn't mean
that after exactly 1 second according
to the system clock, the soundcard has played back 44.100
samples. This is only true by approximation. In fact, the audio
device has an internal clock based on the number of samples played
that we can expose.
If an element with an internal clock needs to synchronize, it needs
to estimate when a time according to the pipeline clock will take
place according to the internal clock. To estimate this, it needs
to slave its clock to the pipeline clock.
If the pipeline clock is exactly the internal clock of an element,
the element can skip the slaving step and directly use the pipeline
clock to schedule playback. This can be both faster and more
accurate.
Therefore, generally, elements with an internal clock like audio
input or output devices will be a clock provider for the pipeline.
When the pipeline goes to the PLAYING state, it will go over all
elements in the pipeline from sink to source and ask each element
if they can provide a clock. The last element that can provide a
clock will be used as the clock provider in the pipeline.
This algorithm prefers a clock from an audio sink in a typical
playback pipeline and a clock from source elements in a typical
capture pipeline.
There exist some bus messages to let you know about the clock and
clock providers in the pipeline. You can see what clock is selected
in the pipeline by looking at the NEW_CLOCK message on the bus.
When a clock provider is removed from the pipeline, a CLOCK_LOST
message is posted and the application should go to PAUSED and back
to PLAYING to select a new clock.
Latency
The latency is the time it takes for a sample captured at timestamp X
to reach the sink. This time is measured against the clock in the
pipeline. For pipelines where the only elements that synchronize against
the clock are the sinks, the latency is always 0 since no other element
is delaying the buffer.
For pipelines with live sources, a latency is introduced, mostly because
of the way a live source works. Consider an audio source, it will start
capturing the first sample at time 0. If the source pushes buffers with
44100 samples at a time at 44100Hz it will have collected the buffer at
second 1. Since the timestamp of the buffer is 0 and the time of the
clock is now >= 1 second, the sink will drop this buffer because it is
too late. Without any latency compensation in the sink, all buffers will
be dropped.
Latency compensation
Before the pipeline goes to the PLAYING state, it will, in addition to
selecting a clock and calculating a base-time, calculate the latency
in the pipeline. It does this by doing a LATENCY query on all the sinks
in the pipeline. The pipeline then selects the maximum latency in the
pipeline and configures this with a LATENCY event.
All sink elements will delay playback by the value in the LATENCY event.
Since all sinks delay with the same amount of time, they will be
relative in sync.
Dynamic Latency
Adding/removing elements to/from a pipeline or changing element
properties can change the latency in a pipeline. An element can
request a latency change in the pipeline by posting a LATENCY
message on the bus. The application can then decide to query and
redistribute a new latency or not. Changing the latency in a
pipeline might cause visual or audible glitches and should
therefore only be done by the application when it is allowed.